Manufacturer: |
NVent NuHeat |
Model Number(s): |
Signature |
Driver Name |
NuHeat Signature |
Driver Version |
24.06.10.00 |
g! Core Module Version: |
8.5 Build 18 |
Driver Developer: |
Innovo |
Document Revision Date: |
June 10, 2024 |
This is a two-way driver to control and get feedback from the NuHeat Signature Floor Heating controllers.
The Elan controller is capable of controlling, querying and providing feedback for multiple NuHeat Signature units.
The following options are supported :
This Driver supports
The following playback options are not supported :
Any feature not specifically noted as supported should be assumed to be unsupported.
IMPORTANT NOTE:
It is recommended that you follow the below installation process in order to ensure you are running the latest version of the [driver].
Note: If the driver doesn’t appear under the Communication Type then make sure that the NuHeat Signature driver is extracted to the same folder where all the other drivers are installed from. It’s good practice to create one folder on the computer where all the third party EDRVC files live.
Note: If the driver still does not appear, do the following:
The following table provides settings used in Configurator …Please refer to the Configurator Reference Guide for more details.
In the table below:
Devices | Variable Name | Settings | Comments |
Climate | Name | User Defined (Default: NuHeat Signature Pro, NuHeat Signature Climate) | |
System # | <Auto Detect> | ||
Device Type | Ethernet | ||
Driver Name | NuHeat Signature Pro | ||
Driver Version | <Auto Detect> | ||
Driver Vendor | Innovo |
Activation KEY |
<User Defined> |
||
Polling |
<User Defined> |
IP Address | <User Defined> | ||
Input / Output | Display Name | <User Defined> (Default: NuHeat SignatureInput) | |
System # | <Auto Detect> | ||
Source Device | <User Defined> (Default: NuHeat SignatureInput) |
The driver uses the Native Elan Climate Interface. Turn the system on / off and schedule from the interface.
Notes: The system uses the cloud to communicate so there will be a notable delay from when a button is pushed to when the action is taken to the feedback sent back to Elan.
If the system is set to Fahrenheit, makes the same setting is applied in the NuHeat Signature App when setting up devices.
In order to take advantage of on/off functions, the thermostat must be assigned to a group. Each group can have one thermostat or more depending on your setup. Innovo recommends that at a minimum each thermostat be added to one group. Remember that if multiple thermostats below to a group, if you turn off one thermostat, all the thermostats belonging to that group will also be turned off. This is by design from NuHeat.
To Add a thermostat to a group, use the online NVent account screen. The driver will automatically pull this data.