Innovo Wiki

Innovo Wiki

Loading the knowledge...

Intellifire Using the Driver

Estimated reading: 3 minutes

Using the Driver as a Climate Device

Modes:

Off – System Off

Auto – Thermostat Mode – This will override Flame Height and allow setting of Setpoint.  If set point is below Room Temp, the fireplace will remain off.  This is used for controlled heating.

Flame Height x – This will disable Thermostat Mode and set Flame Height to x.  Flame Height has a maximum runtime of 9 hours.  After that it will be automatically turned off by the Intellifire controller.

Display

Room Temperature – Room Temperature from hand held remote.  Required for Thermostat Operations.

Set Point – Available in Auto Mode Only.  Will automatically control flame height based on Room / Set Point Temperature scale.  Blinking means system is heating.

Fan Levels

1 – Off

2 – Quiet

3 – Low

4 – Medium

5 – High

Turning on the Fan, will automatically turn on the Mode to the last known Flame Height and Fan Speed.  The Flame Height will turn on within 15 seconds.  The Fan has a system delay of 3 minutes.  While the UI will show fan on to the selected speed, the fan may not actually come on until the fireplace has been on for 3 minutes or longer.  Refrain from turning the Fan On / Off if the fan doesn’t kick in immediately.

Light Dimmer

Create a Dimmable lighting control in order to operate the light (Or use Elan’s built-in features)

0 – Off

1 – 33% – Level 1

34 – 66 – Level 2

>66 – Maximum

Slide will auto adjust to the nearest highest percentage.  For example sliding the scale to 10 will adjust the light level 1.  Sliding the scale to 65 will set it to level 2.  0 is explicit off.

Flame Height Dimmer

Create a Dimmable lighting control in order to operate the Flame Height and to use Elan Built lighting schedule

0 – Off

1 – 20% – Flame Height 1

21 – 40% – Flame Height 2

41 – 60% – Flame Height 3

61 – 80% – Flame Height 4

81% – Flame Height 3

Slide will auto adjust to the nearest highest percentage.  For example sliding the scale to 10 will adjust the light level 1.  Sliding the scale to 65 will set it to level 4.  0 is explicit off.

As a Lighting Device

This is the same as “Cold Weather” on the app.  This should be set once and only changed as needed for winter operations in cold climate in accordance with the manufacturer’s recommendation.  This button is not accessed frequently and should not be made easily available for end users.

This is a custom Home Page.  Create as needed